International Standards and Conformity Assessment for all electrical, electronic and related technologies

SC 77B

High frequency phenomena

 

Detail

Committee
Working Groups
Project Leader

Current

Status

Frcst Pub

Date

Stability

Date

SC 77BWG 10 J. MaasPPUB2013-102021

History

Stage
Document
Downloads
Decision Date
Target Date
1CD
77B/624/CD PDF file 1253 kB
2009-11-27 
AMW
77B/623/MCR PDF file 81 kB
2009-11-27 
CDM
77B/635/CC Word file 813 kB
PDF file 628 kB
2010-03-192010-04
A2CD
77B/635A/CC Word file 731 kB
PDF file 1033 kB
2010-11-192010-05
2CD
77B/647/CD PDF file 1420 kB
2011-02-112011-01
CDM
77B/652A/CC Word file 813 kB
PDF file 780 kB
2011-06-242011-06
ACDV
77B/652B/CC Word file 776 kB
PDF file 785 kB
2011-11-042011-11
CCDV
77B/675/CDV PDF file 1644 kB
PDF file 1405 kB
2012-06-152012-03
AFDIS
77B/680/RVC Word file 547 kB
PDF file 420 kB
2012-12-212013-02
DECFDIS
2013-06-282013-01
RFDIS
2013-07-032013-07
CFDIS
77B/691/FDIS

2013-07-262013-09
APUB
77B/704/RVD PDF file 189 kB
2013-09-302013-09
BPUB
2013-10-012013-10
PPUB
2013-10-232013-11
 2020-07

Abstract

IEC 61000-4-6:2013 relates to the conducted immunity requirements of electrical and electronic equipment to electromagnetic disturbances coming from intended radio-frequency (RF) transmitters in the frequency range 150 kHz up to 80 MHz. Equipment not having at least one conducting wire and/or cable (such as mains supply, signal line or earth connection) which can couple the equipment to the disturbing RF fields is excluded from the scope of this publication. The object of this standard is to establish a common reference for evaluating the functional immunity of electrical and electronic equipment when subjected to conducted disturbances induced by RF fields. The test method documented in IEC 61000-4-6:2013 describes a consistent method to assess the immunity of an equipment or system against a defined phenomenon. This fourth edition cancels and replaces the third edition published in 2008 and constitutes a technical revision. It includes the following significant technical changes with respect to the previous edition:
- use of the CDNs;
- calibration of the clamps;
- reorganization of Clause 7 on test setup and injection methods;
- Annex A which is now dedicated to EM and decoupling clamps;
- Annex G which now addresses the measurement uncertainty of the voltage test level;
- and informative Annexes H, I and J which are new. The contents of the corrigendum of June 2015 have been included in this copy.

Project

IEC 61000-4-6:2013 ED4

Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields

 

 

Associated Documents:

77B/819/DL

PDF file 103 kB
77B/810A/RR

PDF file 90 kB
77B/809/INF

PDF file 239 kB
Word file 111 kB
77B/789/RM

PDF file 313 kB
77B/782/DC

PDF file 97 kB
77B/752/RM

PDF file 189 kB
SMB/4821/DL

PDF file 252 kB