International Standards and Conformity Assessment for all electrical, electronic and related technologies

TC 106

Methods for the assessment of electric, magnetic and electromagnetic fields associated with human exposure

 

Detail

Committee
Working Groups
Project Leader

Current

Status

Frcst Pub

Date

Stability

Date

TC 106PT 62209-3Mr Jafar KeshvariPPUB2019-092022

History

Stage
Document
Downloads
Decision Date
Target Date
PNW
106/289/NP PDF file 197 kB
2013-08-30 
ANW
106/305/RVN PDF file 423 kB
2014-05-232014-01
ACD
2014-05-242014-05
ACDV
106/305A/RVN PDF file 633 kB
2017-09-012017-12
ACDV
106/305B/RVN  
2017-09-012017-12
ACDV
106/305C/RVN PDF file 221 kB
2017-09-012017-12
TCDV
2018-05-222018-08
CCDV
106/457/CDV
PDF file 2979 kB
2018-07-132018-07
CCDV
106/457(F)/CDV PDF file 3021 kB
2018-07-132018-07
PRVC
2018-10-052018-10
AFDIS
106/474/RVC PDF file 658 kB
Word file 132 kB
2018-12-072018-12
AFDIS
106/474A/RVC PDF file 692 kB
Word file 162 kB
2018-12-072018-12
TFDIS
2019-01-302019-01
DECFDIS
2019-03-142019-03
RFDIS
2019-03-292019-04
CFDIS
106/494/FDIS

2019-06-282019-06
PRVD
2019-08-092019-08
APUB
106/497/RVD PDF file 342 kB
2019-08-162019-08
BPUB
2019-08-162019-08
PPUB
2019-09-242019-09
  

Abstract

IEC 62209-3: 2019 specifies measurement protocols and test procedures for the reproducible measurement of peak spatial-average specific absorption rate (psSAR) induced inside a simplified model of a human head or body by radio-frequency (RF) transmitting devices, with a specified measurement uncertainty. Requirements are provided for psSAR assessment using vector measurement-based systems. Such systems determine the psSAR by three-dimensional (3D) field reconstruction within the volume of interest in accordance with the requirements herein for the measurement system, calibration, uncertainty assessment and validation methods. The protocols and procedures apply for the psSAR assessments covering a significant majority of people including children during use of wireless communication devices operated in close proximity to the head or body.
This document is applicable to wireless communication devices intended to be used at a position near the human head or body at distances up to and including 200 mm. This document may be employed to evaluate SAR compliance of different types of wireless communication devices used next to the ear, in front of the face, mounted on the body, combined with other RF-transmitting or non-transmitting devices or accessories (e.g. belt-clip), or embedded in garments. The overall applicable frequency range is from 600 MHz to 6 GHz.
The system validation procedures provided within this document cover frequencies from 600 MHz to 6 GHz.
With a vector measurement-based system this document can be employed to evaluate SAR compliance of different types of wireless communication devices.
The wireless communication device categories covered include but are not limited to mobile telephones, cordless microphones, auxiliary broadcast devices and radio transmitters in personal computers, desktop and laptop devices, multi-band, multi-antenna, and push-to-talk devices.
Key Words: Human Exposure, Hand-Held and Body Mounted Wireless Communication Devices.

Project

IEC 62209-3:2019 ED1

Measurement procedure for the assessment of specific absorption rate of human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Part 3: Vector measurement-based systems (Frequency range of 600 MHz to 6 GHz)

 

 

Associated Documents:

106/357/RM

PDF file 258 kB
SMB/6250/DL

PDF file 559 kB
SMB/6186/DL

PDF file 474 kB
SMB/5970/DL

PDF file 471 kB