International Standards and Conformity Assessment for all electrical, electronic and related technologies

TC 56

Dependability

 

Detail

Committee
Working Groups
Project Leader

Current

Status

Frcst Pub

Date

Stability

Date

TC 56WG 2Mr Yefim Haim MichlinPPUB2019-122025

History

Stage
Document
Downloads
Decision Date
Target Date
ACD
56/1760/RR PDF file 86 kB
2017-11-07 
CD
56/1761/CD
PDF file 1846 kB
2017-11-102017-11
PCC
2018-02-022018-02
CDM
56/1768/CC PDF file 245 kB
Word file 180 kB
2018-02-162018-04
A2CD
56/1768A/CC PDF file 273 kB
Word file 224 kB
2018-06-222018-06
2CD
56/1786/CD
PDF file 1726 kB
2018-07-062018-06
PCC
2018-09-282018-09
ACDV
56/1818/CC PDF file 214 kB
Word file 47 kB
2018-10-122018-12
ACDV
56/1818A/CC PDF file 226 kB
Word file 50 kB
2018-10-122018-12
TCDV
2018-11-302019-01
CCDV
56/1831/CDV
PDF file 1729 kB
PDF file 1707 kB
2019-01-182019-01
PRVC
2019-04-122019-04
AFDIS
56/1841/RVC PDF file 204 kB
Word file 42 kB
2019-04-192019-11
AFDIS
56/1841A/RVC PDF file 206 kB
Word file 44 kB
2019-04-192019-11
TFDIS
2019-06-062019-06
DECFDIS
2019-07-232019-07
RFDIS
2019-08-092019-08
CFDIS
56/1852/FDIS

2019-09-272019-11
PRVD
2019-11-082019-11
APUB
56/1873/RVD PDF file 267 kB
2019-11-152019-11
BPUB
2019-11-152019-11
PPUB
2019-11-222019-12
  

Abstract

IEC 61123:2019 is intended to define a procedure to verify if a reliability of an item/system complies with the stated requirements. The requirement is assumed to be specified as the percentage of success (success ratio) or the percentage of failures (failure ratio). This document can be used where a number of items are tested (number of trials performed) and classified as passed or failed. It can also be used where one or a number of items are tested repeatedly. The procedures are based on the assumption that the probability of success or failure is the same from trial to trial (statistically independent events). Plans for fixed trial/failure terminated tests as well as truncated sequential probability ratio tests (SPRTs) are included. This document contains extensive tables with ready-to-use SPRT plans and their characteristics for equal and non-equal risks for supplier and customer. In the case of the reliability compliance tests for constant failure rate/intensity, IEC 61124 applies. This second edition cancels and replaces the first edition published in 1991. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
The sequential probability ratio test (SPRT) [1, 2][1] has been significantly developed in recent years [3, 4, 5]. This edition contains shorter and accurate tests, a wide range of test plans, and significant additional characteristic data, as follows:
the tests are significantly truncated (the maximum trial numbers are low) without substantially increasing the expected number of trials to decision (ENT);
the true producer’s and consumer’s risks (α', β') are given and very close to the nominal (α, β);
the range of the test parameters is wide (failure ratio, risks and discrimination ratio);
the test plans include various risk ratios (not restricted to equal risks only);
the values of ENT are accurate and given in the relevant region (for practical use);
guidelines for extension of the test sets (interpolation and extrapolation) are included.
In Annex C, the use of the cumulative binomial distribution function of Excel that simplifies the procedure of designing has been added (Clause C.3).
Keywords: verify if a reliability of an item/system complies with the stated requirements

Project

IEC 61123:2019 ED2

Reliability testing - Compliance test plans for success ratio