International Standards and Conformity Assessment for all electrical, electronic and related technologies

TC 106

Methods for the assessment of electric, magnetic and electromagnetic fields associated with human exposure

 

Detail

Committee
Working Groups
Project Leader

Current

Status

Frcst Pub

Date

Stability

Date

TC 106PT 62209 A. FaraonePPUB2010-042020

History

Stage
Document
Downloads
Decision Date
Target Date
PNW
106/90/NP PDF file 1258 kB
2005-02-18 
ANW
106/100A/RVN PDF file 381 kB
2005-09-022005-07
1CD
106/132/CD PDF file 3822 kB
2007-07-062007-02
A2CD
106/144/CC Word file 1768 kB
PDF file 1025 kB
2008-01-042007-11
ACDV
106/144A/CC Word file 2048 kB
PDF file 791 kB
2008-07-182008-03
CCDV
106/162/CDV PDF file 2032 kB
PDF file 2132 kB
2008-10-032008-09
AFDIS
106/187/RVC Word file 983 kB
PDF file 470 kB
2009-09-182009-06
DECFDIS
2009-11-182009-10
RFDIS
2009-11-252009-12
CFDIS
106/195/FDIS
2010-01-082010-02
APUB
106/200/RVD PDF file 114 kB
2010-03-182010-03
BPUB
2010-03-192010-03
PPUB
2010-03-302010-04
 2017-12

Abstract

IEC 62209-2:2010 is applicable to any wireless communication device capable of transmitting electromagnetic fields (EMF) intended to be used at a position near the human body, in the manner described by the manufacturer, with the radiating part(s) of the device at distances up to and including 200 mm from a human body, i.e. when held in the hand or in front of the face, mounted on the body, combined with other transmitting or non-transmitting devices or accessories (e.g. belt-clip, camera or Bluetooth add-on), or embedded in garments. For transmitters used in close proximity to the human ear, the procedures of IEC 62209-1:2005 are applicable. IEC 62209-2:2010 is applicable for radio frequency exposure in the frequency range of 30 MHz to 6 GHz, and may be used to measure simultaneous exposures from multiple radio sources used in close proximity to human body. Definitions and evaluation procedures are provided for the following general categories of device types:
- body-mounted,
- body-supported,
- desktop,
- front-of-face,
- hand-held,
- laptop,
- limb-mounted,
- multi-band,
- push-to-talk,
- clothing-integrated. The types of devices considered include but are not limited to mobile telephones, cordless microphones, auxiliary broadcast devices and radio transmitters in personal computers. IEC 62209-2:2010 gives guidelines for a reproducible and conservative measurement methodology for determining the compliance of wireless devices with the SAR limits. The contents of the corrigendum of June 2010 have been included in this copy.

Project

IEC 62209-2:2010 ED1

Human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Human models, instrumentation, and procedures - Part 2: Procedure to determine the specific absorption rate (SAR) for wireless communication devices used in close proximity to the human body (frequency range of 30 MHz to 6 GHz)

 

Remark:


 

Associated Documents:

106/409/RR

PDF file 96 kB
106/386/RM

PDF file 201 kB
106/357/RM

PDF file 258 kB
106/324/RM

PDF file 290 kB
106/295A/RM

PDF file 321 kB
SMB/3690/DL

PDF file 177 kB
SMB/3430/DL

PDF file 185 kB
SMB/3333/DL

PDF file 304 kB