SC 34D

Luminaires

 

Detail

Committee
Working Groups
Project Leader

Current

Status

Frcst Pub

Date

Stability

Date

SC 34DWG 1Mr Franco RusnatiPPUB2020-082023

History

Stage
Document
Downloads
Decision Date
Target Date
ACD
34D/1309/RR PDF file 34 kB
2017-09-082017-09
CD
34D/1310/CD
PDF file 28 kB
2017-09-15 
PCC
2017-12-082017-12
CDM
34D/1341/CC PDF file 50 kB
Word file 51 kB
2018-01-052018-01
ACDV
34D/1341A/CC PDF file 50 kB
Word file 50 kB
2018-04-132019-04
TCDV
2019-04-182019-06
CCDV
34D/1477/CDV PDF file 1296 kB

PDF file 785 kB
2019-06-072019-06
PRVC
2019-08-302019-08
AFDIS
34D/1501/RVC PDF file 267 kB
Word file 70 kB
2019-09-202020-04
AFDIS
34D/1501A/RVC PDF file 275 kB
Word file 92 kB
2019-09-202020-04
DECFDIS
2020-03-052020-04
RFDIS
2020-03-192020-03
CFDIS
34D/1546/FDIS
2020-05-152020-06
PRVD
2020-06-262020-06
APUB
34D/1560/RVD PDF file 68 kB
2020-07-102020-07
BPUB
2020-07-102020-07
PPUB
2020-08-172020-08
  

Abstract

IEC 60598-1:2020 is available as IEC 60598-1:2020 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.

IEC 60598-1:2020 specifies general requirements for luminaires, incorporating electric light sources for operation from supply voltages up to 1 000 V. The requirements and related tests of this document cover: classification, marking, mechanical construction, electrical construction and photobiological safety. This ninth edition cancels and replaces the eighth edition published in 2014 and Amendment 1:2017. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- Revision of Clause 4.30, Fixing cover live parts of non-user replaceable light source;
- Subclause 4.24.2, Blue Light Hazard: removal of Risk Group 0;
- Subclause 5.2.16: additional requirements for AC mains appliance inlets related to IEC 61984;
- Addition of Subclause 3.3.25, UV protection of cable;
- Addition of Clause 4.34, Inclusion of EMF safety requirements (IEC 62493);
- Revision of the requirements for functional earth and protective earth;
- Addition of Clause 4.35, Protection against fast rotating parts;
- Revision of Clause 3.2, Rated voltage marking;
- Revision of Subclause 5.2.10, Cord anchorage;
- Revision of Annex G for touch current and protective conductor current test set-up;
- Addition of requirements for constant light output function and programmable current output;
- Revision of Subclause 8.2.3 c), touch voltage limits for interrupted DC voltage;
- Introduction of PELV;
- Introduction of Ethernet power supply connection for luminaires (PoE);
- Section 9, Introduction of IPX9;
- Addition of Subclause 3.3.26 for wall mounted luminaires;
- Revision of Annex D introducing alternative thermal tests for luminaires with ta marking higher than 25°C;
- Revision of Table 10.3 and Subclause 3.3.19 for protective conductor current limits;
- Track-mounted luminaires: cross reference to Annex A of IEC 60570:2003/AMD2:2019;
- Revision of Subclause 10.2.2, alternative DC electric strength test;
- Revision of Annex D for recessed luminaires;
- Subclause 4.12.5: revision of Table 4.2 for torque test on metal glands;
- Revision of use of bridging capacitors in luminaires;
- Revision of electrical connection to class III plugs.


Project

IEC 60598-1:2020 ED9

Luminaires - Part 1: General requirements and tests