SC 23E |
Circuit-breakers and similar equipment for household use |

Project Reference |
Document Reference |
Init. Date |
Current Stage |
Next Stage |
Working Group |
Project Leader |
Fcst. Publ. Date |
---|---|---|---|---|---|---|---|
IEC 60755-2 ED1
General safety requirements for residual current operated protective devices Part 2: Residual current operated protective devices for DC systems
|
23E/1134/CD | 2019-05 |
CDM
2020-11 |
2021-05 |
WG 2 | Jean-François REY | 2022-05 |
IEC 60898-3/AMD1 ED1
Amendment 1 - Electrical accessories - Circuit-breakers for overcurrent protection for household and similar installations - Part 3: Circuit-breakers for DC operation
|
23E/1228A/RR | 2021-02 |
TCDV
2021-02 |
CCDV
2021-04 |
WG 1 | Giovanni Cassinelli | 2022-05 |
IEC 61008-1 ED4
Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) - Part 1: General rules
|
23E/1223/CD | 2020-11 |
PCC
2021-02 |
2021-03 |
WG 2 | Jean-François REY | 2024-06 |
IEC 61008-2-1 ED2
Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCB's). Part 2-1: RCCBs according to 4.1.1
|
23E/1219/CD | 2020-11 |
PCC
2021-02 |
2021-03 |
WG 2 | Jean-François REY | 2024-06 |
IEC 61008-2-2 ED2
Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCB's) - Part 2-2: RCCBs according to 4.1.2, 4.1.3, 4.1.4, 4.1.5 and 4.1.6
|
23E/1220/CD | 2020-11 |
PCC
2021-02 |
2021-03 |
WG 2 | Jean-François REY | 2024-06 |
IEC 61009-1 ED4
Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBOs) - Part 1: General rules
|
23E/1224/CD | 2020-11 |
PCC
2021-02 |
2021-03 |
WG 2 | Jean-François REY | 2024-06 |
IEC 61009-2-1 ED2
Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBO's) - Part 2-1: RCBOs according to 4.1.1
|
23E/1221/CD | 2020-11 |
PCC
2021-02 |
2021-03 |
WG 2 | Jean-François REY | 2024-06 |
IEC 61009-2-2 ED2
Residual current operated circuit-breakers with integral overcurrent protection for household and similar uses (RCBO's) - Part 2-2: RCBOs according to 4.1.2, 4.1.3, 4.1.4, 4.1.5 and 4.1.6
|
23E/1222/CD | 2020-11 |
PCC
2021-02 |
2021-03 |
WG 2 | Jean-François REY | 2024-06 |
IEC 61540 ED2
Electrical accessories - Portable residual current devices without integral overcurrent protection for household and similar use (PRCDs)
|
23E/1225/CD | 2020-11 |
PCC
2021-02 |
2021-03 |
WG 2 | Jean-François REY | 2024-03 |
IEC 61543 ED2
Residual current-operated protective devices (RCDs) for household and similar use - Electromagnetic compatibility
|
23E/1213/CD | 2020-11 |
CD
2020-11 |
PCC
2021-03 |
WG 2 | Jean-François REY | 2022-11 |
IEC 62606/AMD2 ED1
Amendment 2 - General requirements for arc fault detection devices
|
23E/1160/CD | 2019-11 |
CDM
2020-11 |
2021-05 |
WG 2 | Jean-François REY | 2022-05 |
IEC 62752 ED2
In-cable control and protection device for mode 2 charging of electric road vehicles (IC-CPD)
|
23E/1212/CD | 2019-12 |
PCC
2021-02 |
2021-03 |
WG 7 | Uwe Blosfeld | 2022-09 |
IEC 62873-3-3 ED2
Residual current operated circuit-breakers for household and similar use - Part 3-3: Specific requirements for RCDs with screw-type terminals for external untreated aluminium conductors and with aluminium screw-type terminals for use with copper or with aluminium conductors
|
23E/1218/CD | 2018-11 |
PCC
2021-02 |
2021-03 |
WG 2 | Jean-François REY | 2022-05 |