International Standards and Conformity Assessment
for all electrical, electronic and related technologies
SC 77C |
High power transient phenomena |

Project Reference | Current Stage | Language | Frcst Date | CLC | Document Reference | Downloads |
|---|---|---|---|---|---|---|
IEC/TR 61000-1-3 Ed. 1.0Electromagnetic compatibility (EMC) - Part 1-3: General - The effects of high-altitude EMP (HEMP) on civil equipment and systems | PPUB
| E | no | Webstore | ||
IEC/TR 61000-1-5 Ed. 1.0Electromagnetic compatibility (EMC) - Part 1-5: General - High power electromagnetic (HPEM) effects on civil systems | PPUB
| E | Webstore | |||
IEC 61000-2-9 Ed. 1.0Electromagnetic compatibility (EMC) - Part 2: Environment - Section 9: Description of HEMP environment - Radiated disturbance. Basic EMC publication | PPUB
| B | yes | Webstore | ||
IEC 61000-2-10 Ed. 1.0Electromagnetic compatibility (EMC) - Part 2-10: Environment - Description of HEMP environment - Conducted disturbance | PPUB
| B | yes | Webstore | ||
IEC 61000-2-11 Ed. 1.0Electromagnetic compatibility (EMC) - Part 2-11: Environment - Classification of HEMP environments
| PPUB
| B | yes | Webstore | ||
IEC 61000-2-13 Ed. 1.0Electromagnetic compatibility (EMC) - Part 2-13: Environment - High-power electromagnetic (HPEM) environments - Radiated and conducted | PPUB
| E | yes | Webstore | ||
IEC 61000-4-23 Ed. 1.0Electromagnetic compatibility (EMC) - Part 4-23: Testing and
measurement techniques - Test methods for protective devices for HEMP and other radiated disturbances
| PPUB
| B | yes | Webstore | ||
IEC 61000-4-24 Ed. 1.0Electromagnetic compatibility (EMC) - Part 4: Testing and
measurement techniques - Section 24: Test methods for protective
devices for HEMP conducted disturbance - Basic EMC Publication
| PPUB
| B | yes | Webstore | ||
IEC 61000-4-24 Ed. 2.0Electromagnetic compatibility (EMC) - Part 4: Testing and measurement techniques - Section 24: Test methods for protective devices for HEMP conducted disturbance | AMW
| E | 2015-09 | no | 77C/219 | |
IEC 61000-4-25 Ed. 1.0Electromagnetic compatibility (EMC) - Part 4-25: Testing and measurement techniques - HEMP immunity test methods for equipment and systems
| PPUB
| E | yes | Webstore | ||
IEC 61000-4-25 Ed. 1.1Electromagnetic compatibility (EMC) - Part 4-25: Testing and measurement techniques - HEMP immunity test methods for equipment and systems | PPUB
| B | Webstore | |||
IEC 61000-4-25 am1 Ed. 1.0Amendment 1 - Electromagnetic compatibility (EMC) - Part 4-25: Testing and measurement techniques - HEMP immunity test methods for equipment and systems | PPUB
| B | 2012-03 | yes | Webstore | |
IEC/TR 61000-4-32 Ed. 1.0Electromagnetic compatibility (EMC) - Part 4-32: Testing and measurement techniques - High-altitude electromagnetic pulse (HEMP) simulator compendium | PPUB
| E | no | Webstore | ||
IEC 61000-4-33 Ed. 1.0Electromagnetic compatibility (EMC) - Part 4-33: Testing and measurement techniques - Measurement methods for high-power transient parameters | PPUB
| E | yes | Webstore | ||
IEC/TR 61000-4-35 Ed. 1.0Electromagnetic compatibility (EMC) - Part 4-35: Testing and measurement techniques - HPEM simulator compendium | PPUB
| E | 2009-07 | no | Webstore | |
IEC 61000-4-36 Ed. 1.0Electromagnetic compatibility (EMC) - Testing and measurement techniques - IEMI Immunity Test Methods for Equipment and Systems | ANW
| E | 2014-11 | 77C/206 | ||
IEC/TR 61000-5-3 Ed. 1.0Electromagnetic compatibility (EMC) - Part 5-3: Installation and mitigation guidelines - HEMP protection concepts | PPUB
| B | yes | Webstore | ||
IEC/TS 61000-5-4 Ed. 1.0Electromagnetic compatibility (EMC) - Part 5: Installation and mitigation guidelines - Section 4: Immunity to HEMP - Specification for protective devices against HEMP radiated disturbance. Basic EMC Publication | PPUB
| B | Webstore | |||
IEC 61000-5-5 Ed. 1.0Electromagnetic compatibility (EMC) - Part 5: Installation and mitigation guidelines - Section 5: Specification of protective devices for HEMP conducted disturbance. Basic EMC Publication | PPUB
| B | yes | Webstore | ||
IEC/TR 61000-5-6 Ed. 1.0Electromagnetic compatibility (EMC) - Part 5-6: Installation and mitigation guidelines - Mitigation of external EM influences | PPUB
| E | no | Webstore | ||
IEC 61000-5-7 Ed. 1.0Electromagnetic compatibility (EMC) - Part 5-7: Installation and mitigation guidelines - Degrees of protection by enclosures against electromagnetic disturbances (EM code)
| PPUB
| B | yes | Webstore | ||
IEC/TS 61000-5-8 Ed. 1.0Electromagnetic compatibility (EMC) - Part 5-8: Installation and mitigation guidelines - HEMP protection methods for the distributed infrastructure | PPUB
| E | 2009-09 | no | Webstore | |
IEC/TS 61000-5-9 Ed. 1.0Electromagnetic compatibility (EMC) - Part 5-9: Installation and mitigation guidelines - System-level susceptibility assessments for HEMP and HPEM | PPUB
| E | 2009-08 | no | Webstore | |
IEC 61000-6-6 Ed. 1.0Electromagnetic compatibility (EMC) - Part 6-6: Generic standards - HEMP immunity for indoor equipment | PPUB
| B | yes | Webstore |