International Standards and Conformity Assessment for all electrical, electronic and related technologies

TC 106

Methods for the assessment of electric, magnetic and electromagnetic fields associated with human exposure

 
export to xls file

TC 106 Project files (39)

Project

Reference

Current

Stage

Language

Frcst

Date

CLC

Document

Reference

Downloads
PNW 106-207 ED1

Guidance for evaluating exposure from multiple electromagnetic sources: Specific Requirements for assessing the Specific Absorption Rate (SAR) from multiple transmitters used in close proximity to the human head

DEL
  • DEL
  • Deleted items
EN U 106/207/NP PDF file 280 kB
PNW 106-223 ED1

EN 50527-1: Procedure for the assessment of the exposure to electromagnetic fields of workers bearing active implantable medical devices - Part 1: General

DEL
  • DEL
  • Deleted items
EN U 106/223/NP PDF file 472 kB
PNW 106-224 ED1

EN 50519: Assessment of the emission of electric and magnetic fields of industrial induction heating equipment related to the exposure of workers

DEL
  • DEL
  • Deleted items
EN U 106/224/NP PDF file 325 kB
PNW 106-226 ED1

EN 50554: Basic standard for the in-situ assessment of a broadcast site related to general public exposure to radio frequency electromagnetic fields

DEL
  • DEL
  • Deleted items
EN U 106/226/NP PDF file 617 kB
IEC 61786-1:2013 ED1

Measurement of DC magnetic, AC magnetic and AC electric fields from 1 Hz to 100 kHz with regard to exposure of human beings - Part 1: Requirements for measuring instruments

PPUB
  • PPUB
  • Publication issued
EN-FR 2014-01 Y Webstore
IEC 61786-2:2014 ED1

Measurement of DC magnetic, AC magnetic and AC electric fields from 1 Hz to 100 kHz with regard to exposure of human beings - Part 2: Basic standard for measurements

PPUB
  • PPUB
  • Publication issued
EN-FR 2014-12 N Webstore
IEC 62110:2009 ED1

Electric and magnetic field levels generated by AC power systems - Measurement procedures with regard to public exposure

PPUB
  • PPUB
  • Publication issued
EN-FR 2009-09 Y Webstore
IEC 62110:2009/COR1:2015 ED1

Corrigendum 1 - Electric and magnetic field levels generated by AC power systems - Measurement procedures with regard to public exposure

PPUB
  • PPUB
  • Publication issued
EN U Webstore
IEC 62209/FRAG1 ED1

Proposal from Switzerland: Evaluation of the Human Exposure to Radio Fields from Handheld and Body-Mounted Wireless Communication Devices in the Frequency Range 30 MHz to 6 GHz (Human models, Instrumentation, Procedures)

MERGED
  • MERGED
  • Fragment merged
EN U 106/8/NP Word file 31 kB
PDF file 38 kB
IEC 62209-1:2016 ED2

Measurement procedure for the assessment of specific absorption rate of human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Part 1: Devices used next to the ear (Frequency range of 300 MHz to 6 GHz)

PPUB
  • PPUB
  • Publication issued
EN-FR 2016-08 Y Webstore
IEC 62209-1:2005 ED1

Human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Human models, instrumentation, and procedures - Part 1: Procedure to determine the specific absorption rate (SAR) for hand-held devices used in close proximity to the ear (frequency range of 300 MHz to 3 GHz)

DELPUB
  • DELPUB
  • Publication Deleted
EN-FR 2005-03 N 106/84/FDIS PDF file 3681 kB
IEC 62209-2:2010 ED1

Human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Human models, instrumentation, and procedures - Part 2: Procedure to determine the specific absorption rate (SAR) for wireless communication devices used in close proximity to the human body (frequency range of 30 MHz to 6 GHz)

PPUB
  • PPUB
  • Publication issued
EN-FR 2010-04 Y Webstore
DEL
  • DEL
  • Deleted items
FR 2010-04 U
IEC 62209-2:2010/COR1:2010 ED1

Corrigendum 1 - Human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Human models, instrumentation, and procedures - Part 2: Procedure to determine the specific absorption rate (SAR) for wireless communication devices used in close proximity to the human body (frequency range of 30 MHz to 6 GHz)

PPUB
  • PPUB
  • Publication issued
EN-FR U Webstore
IEC 62209-3 ED1

Human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Human models, instrumentation, and procedures - Part 3: Vector probe systems (Frequency range of 100 MHz to 6 GHz)

ACD
  • ACD
  • Approved for CD
EN 2019-12 U 106/289/NP PDF file 197 kB
IEC 62226-1:2004 ED1

Exposure to electric or magnetic fields in the low and intermediate frequency range - Methods for calculating the current density and internal electric field induced in the human body - Part 1: General

PPUB
  • PPUB
  • Publication issued
EN-FR Y Webstore
IEC 62226-2-1:2004 ED1

Exposure to electric or magnetic fields in the low and intermediate frequency range - Methods for calculating the current density and internal electric field induced in the human body - Part 2-1: Exposure to magnetic fields - 2D models

PPUB
  • PPUB
  • Publication issued
EN-FR Y Webstore
IEC 62226-3-1:2007 ED1

Exposure to electric or magnetic fields in the low and intermediate frequency range - Methods for calculating the current density and internal electric field induced in the human body - Part 3-1: Exposure to electric fields - Analytical and 2D numerical models

PPUB
  • PPUB
  • Publication issued
EN-FR 2007-06 Y Webstore
IEC 62226-3-1:2007/AMD1:2016 ED1

Amendment 1 - Exposure to electric or magnetic fields in the low and intermediate frequency range - Methods for calculating the current density and internal electric field induced in the human body - Part 3-1: Exposure to electric fields - Analytical and 2D numerical models

PPUB
  • PPUB
  • Publication issued
EN-FR 2016-10 Y Webstore
IEC 62232 ED2

Determination of RF field strength, power density and SAR in the vicinity of radiocommunication base stations for the purpose of evaluating human exposure

AFDIS
  • AFDIS
  • Approved for FDIS
EN 2017-07 Y 106/366A/CDV PDF file 4723 kB

IEC 62232:2011 ED1

Determination of RF field strength and SAR in the vicinity of radiocommunication base stations for the purpose of evaluating human exposure

PPUB
  • PPUB
  • Publication issued
EN-FR 2011-06 N Webstore
IEC 62233 ED2

Measurement methods for electromagnetic fields of household appliances and similar apparatus with regard to human exposure

DEL
  • DEL
  • Deleted items
EN 2017-11 Y
IEC 62233:2005 ED1

Measurement methods for electromagnetic fields of household appliances and similar apparatus with regard to human exposure

PPUB
  • PPUB
  • Publication issued
EN-FR N Webstore
IEC 62311 ED2

Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz - 300 GHz)

ACD
  • ACD
  • Approved for CD
EN 2017-05 Y
IEC 62311:2007 ED1

Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz - 300 GHz)

PPUB
  • PPUB
  • Publication issued
EN-FR 2007-09 Y Webstore
IEC 62334/FRAG 1 ED1

Measurement and Assessment of Human Exposure to High Frequency (9 kHz to 300 GHz) Electromagnetic Fields

MERGED
  • MERGED
  • Fragment merged
EN U 106/25/NP PDF file 25 kB
IEC 62334 ED1

Measurement and Assessment of Human Exposure to High Frequency (9 kHz to 300 GHz) Electromagnetic Fields

DEL
  • DEL
  • Deleted items
EN 2005-06 U 106/25/NP PDF file 25 kB
IEC 62369-1:2008 ED1

Evaluation of human exposure to electromagnetic fields from short range devices (SRDs) in various applications over the frequency range 0 GHz to 300 GHz - Part 1: Fields produced by devices used for electronic article surveillance, radio frequency identification and similar systems

PPUB
  • PPUB
  • Publication issued
EN-FR 2008-09 N Webstore
IEC 62369-2 ED1

Assessment of human exposure to electromagnetic fields in the frequency range 0-300 GHz - Part 2: Fields produced by devices used for Alarms; Alert; Asset tracking, monitoring and protection; Detection; Security; Telecommand and control; Telemetry and similar Short Range and/or Low Power Radio Devices.

DEL
  • DEL
  • Deleted items
EN 2006-05 U 106/41/NP PDF file 777 kB
IEC 62479:2010 ED1

Assessment of the compliance of low-power electronic and electrical equipment with the basic restrictions related to human exposure to electromagnetic fields (10 MHz to 300 GHz)

PPUB
  • PPUB
  • Publication issued
EN-FR 2010-06 Y Webstore
IEC 62577:2009 ED1

Evaluation of human exposure to electromagnetic fields from a stand-alone broadcast transmitter (30 MHz - 40 GHz)

PPUB
  • PPUB
  • Publication issued
EN-FR 2009-08 N Webstore
IEC TR 62630:2010 ED1

Guidance for evaluating exposure from multiple electromagnetic sources

PPUB
  • PPUB
  • Publication issued
EN 2010-03 N Webstore
IEC TR 62669:2011 ED1

Case studies supporting IEC 62232 - Determination of RF field strength and SAR in the vicinity of radiocommunication base stations for the purpose of evaluating human exposure

PPUB
  • PPUB
  • Publication issued
EN 2011-06 N Webstore
IEC/IEEE 62704-1 ED1

Recommended Practice for Determining the Peak Spatial-Average Specific Absorption Rate (SAR) in the Human Body from Wireless Communications Devices, 30 MHz - 6 GHz- Part 1: General Requirements for using the Finite Difference Time Domain (FDTD) Method for SAR Calculations

SUSPEND
  • SUSPEND
  • Project Suspended
EN-FR 2017-05 Y 106/356/CDV
PDF file 2686 kB
PDF file 2726 kB
IEC/IEEE 62704-2 ED1

Determining the peak spatial-average Specific Absorption Rate (SAR) in the human body from wireless communications devices, 30 MHz to 6 GHz - Part 2: specific requirements for finite difference time domain (fdtd) modelling of exposure from vehicle mounted antennas

RFDIS
  • RFDIS
  • FDIS received and registered
EN-FR 2017-04 Y 106/351/CDV
PDF file 1936 kB
PDF file 1954 kB
IEC/IEEE 62704-3 ED1

Determining the Peak Spatial-Average Specific Absorption Rate (SAR) in the Human Body from Wireless Communications Devices, 30 MHz - 6 GHz: Specific Requirements for using the Finite-Difference Time-Domain (FDTD) Method for SAR Calculations of Mobile Phones

AFDIS
  • AFDIS
  • Approved for FDIS
EN-FR 2018-03 Y 106/363/CDV
PDF file 1439 kB
PDF file 1473 kB
IEC/IEEE 62704-4 ED1

Recommended practise for determining the Peak Spatial Average Specific Absorption Rate (SAR) in the human body from wireless communications devices, 30 MHz - 6 GHz: General requirements for using the Finite-Element Method (FEM) for SAR calcutaions and specific requirements for modelling vehicle-mounted antennas and personal wireless devices

ACDV
  • ACDV
  • Approved for CDV
EN 2018-09 N 106/371/CD PDF file 852 kB
IEC 62764-1 ED1

Measurement procedures of magnetic field levels generated by electronic and electrical equipment in the automotive environment with respect to human exposure

PCC
  • PCC
  • Preparation of CC
EN 2017-06 U 106/349/CD PDF file 348 kB
IEC PAS 63083 ED1

Specific Absorption Rate (SAR) measurement procedure for Long Term Evolution (LTE) devices

BPUB
  • BPUB
  • Being published
EN 2017-01 U 106/377/PAS PDF file 893 kB